NOC

Home » NOC
  • Link INIX Down
    Friday, 21-07-2017 21:51
    Cause : Routing Problem disisi Router Distriutor INIX
    Effect : Cust. tidak bisa buka beberapa website lokal
    Start Time : Friday, 21-07-2017 18:47
    End Time : Friday, 21-07-2017 20:28
    Duration : 1h 41m
    Status : Close
  • Switch panel 3 ( Blok B27) Cbroadband Down
    Friday, 21-07-2017 10:49
    Cause : Kabel Fo Cut
    Effect : Tidak bisa internet 18 customer
    Start Time : Friday, 21-07-2017 07:05
    End Time : Friday, 21-07-2017 10:30
    Duration : 3h 25m
    Status : Close
  • AP UMA 172.16.169.205 arah Akpar Down
    Thursday, 20-07-2017 10:41
    Cause : AP Heng - Restart Adaptor
    Effect : 3 Customer arah Ap tersebut tidak bisa internet
    Start Time : Thursday, 20-07-2017 09:38
    End Time : Thursday, 20-07-2017 10:39
    Duration : 1h 1m
    Status : Close
  • AP K2 172.16.192.99 Arah tanjung Sari down
    Tuesday, 18-07-2017 18:38
    Cause : AP Heng - Ganti kabel dan anti petir
    Effect : 1 Customer arah Ap tersebut tidak bisa internet
    Start Time : Tuesday, 18-07-2017 17:54
    End Time : Tuesday, 18-07-2017 18:34
    Duration : 40m
    Status : Close
  • FO POP Thamrin Down
    Tuesday, 18-07-2017 17:59
    Cause : FO Problem
    Effect : Penurunan kualitas untuk customer arah POP Thamrin
    Start Time : Tuesday, 18-07-2017 12:12
    End Time : Tuesday, 18-07-2017 17:44
    Duration : 5h 32m
    Status : Close
  • AP K2 172.16.192.99 arah tanjung sari Down
    Tuesday, 18-07-2017 14:15
    Cause : Hardware Failure - ganti motherboard baru
    Effect : 1 customer arah AP tersebut tidak bisa internet
    Start Time : Tuesday, 18-07-2017 08:28
    End Time : Tuesday, 18-07-2017 10:51
    Duration : 2h 23m
    Status : Close
  • AP Tembung 172.16.173.34 (unimed) Down
    Monday, 17-07-2017 16:54
    Cause : Hardware Failure Ganti Radio
    Effect : 5 customer arah AP tersebut tidak bisa internet
    Start Time : Monday, 17-07-2017 13:43
    End Time : Monday, 17-07-2017 16:40
    Duration : 2h 57m
    Status : Close
  • AP K2 - Tanjung Sari 172.16.192.99 down
    Sunday, 16-07-2017 18:37
    Cause : Hardware Failure
    Effect : 1 cust. mengarah ke AP tersebut tidak bisa internet
    Start Time : Sunday, 16-07-2017 14:11
    End Time : Sunday, 16-07-2017 14:39
    Duration : 28m
    Status : Close